Date parsed: 5/12/2000 1:56:49 AM
Date: Fri, 12 May 2000 00:56:49 +0200
> I've found the example:
> <20>This is a mail system warning
> <33>This is a security/auth alert
> <41>This is a syslog daemon alert
> <9>This is a user alert
> <14>This is a user info
>
> But how to assign these numbers?
??
#define KERN_EMERG    "<0>"  /* system is unusable               */
#define KERN_ALERT    "<1>"  /* action must be taken immediately */
#define KERN_CRIT     "<2>"  /* critical conditions              */
#define KERN_ERR      "<3>"  /* error conditions                 */
#define KERN_WARNING  "<4>"  /* warning conditions               */
#define KERN_NOTICE   "<5>"  /* normal but significant condition */
#define KERN_INFO     "<6>"  /* informational                    */
#define KERN_DEBUG    "<7>"  /* debug-level messages             */